RS-485, 1 Pair 24AWG (7x32) Tinned Copper, PE Insulation, Overall Beldfoil®+Tinned Copper Braid(90%) Shield, PVC Outer Jacket, CM

Specifications

Specifications

Product Overview

Suitable ApplicationsRS-485, POS; Computer communications; Low Voltage Analog Signals (4-20ma, 0-10v, ...); Low Voltage Digital Control (24v, …); Line Level Audio; Panel Wiring; serial communication (RS-485 standard) comprising of PLCs, VFDs, HMIs, motors, RTU, SCADA, etc. within noisy environments over long distance, etc.

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Pair(s)124 AWG7x32TC - Tinned Copper

Insulation

ElementMaterialNom. ThicknessNom. Insulation DiameterColor Code
Pair(s)PE - Polyethylene0.023 in (0.58 mm)0.068 in (1.7 mm)White/Blue Stripe & Blue/White Stripe

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%24 AWG (7x32) TC
BraidTinned Copper (TC)90%

Outer Jacket

MaterialNom. ThicknessNom. Diameter
PVC - Polyvinyl Chloride0.035 in (0.89 mm)0.232 in (5.89 mm)
Table NotesJacket OD +/- 0.020
Overall Cable Diameter (Nominal)0.232 in (5.89 mm)

Electrical Characteristics

Electricals

ElementNom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Nom. Characteristic ImpedenceNom. Velocity of Prop.Max. Current
Pair(s)24 Ohm/1000ft12.8 pF/ft (42.0 pF/m)23 pF/ft120 Ohm66%2.1 Amps per Conductor at 25ºC (10°C Temperature Rise)
Nom. Outer Shield DCR3.4 Ohm/1000ft (11 Ohm/km)

High Frequency (Nominal/Typical)

ElementFrequency [MHz]Nom. Insertion Loss (Attenuation)
Pair(s)10.6 dB/100ft

Voltage

UL Voltage Rating
300 V (CM), 30 V (UL AWM 2919)

Mechanical Characteristics

Temperature

UL TemperatureOperating
80°C-30°C to +80°C

Bend Radius

Stationary Min.Installation Min.
2.5 in (64 mm)2.5 in (64 mm)
Max. Pull Tension72.3 lbs (32.8 kg)
Bulk Cable Weight36 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor
Flammability / Reaction to FireUL 1685 UL Loading, IEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca; CPR UKCA Class: Eca
NEC / UL ComplianceArticle 800, CM
AWM ComplianceAWM 2919
CEC / C(UL) ComplianceCM
European Directive ComplianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Plenum Number82841, 89841
Non-Plenum Number9841ZH

History

Update and RevisionRevision Number: 0.555 Revision Date: 03-04-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length|UPC/EAN
Variant_Options 9841.0030:
9841.0030|Chrome|Reel|30 m|8719605022745
Variant_Options 9841 060100:
9841 060100|Chrome|Reel|100 ft|612825259442
Variant_Options 9841.019999:
9841.019999|Chrome|Reel|151 m|8719605022806
Variant_Options 9841.01152:
9841.01152|Chrome|Reel|152 m|8719605022769
Variant_Options 9841.01305:
9841.01305|Chrome|Reel|305 m|8719605022790
Variant_Options 9841 060500:
9841 060500|Chrome|Reel|500 ft|612825259473
Variant_Options 9841 0601000:
9841 0601000|Chrome|Reel|1,000 ft|612825259459
Variant_Options 9841.011000:
9841.011000|Chrome|Reel|1,000 m|8719605022752
Variant_Options 9841.011525:
9841.011525|Chrome|Reel|1,525 m|8719605022776
Variant_Options 9841.012000:
9841.012000|Chrome|Reel|2,000 m|8719605022783
Variant_Options 9841 0605000:
9841 0605000|Chrome|Reel|5,000 ft|612825259480
Variant_Options 9841 06010000:
9841 06010000|Chrome|Reel|10,000 ft|612825259466
Variant_Options 9841.03305:
9841.03305|Violet|Reel|305 m|8719605022837
Variant_Options 9841.031000:
9841.031000|Violet|Reel|1,000 m|8719605022820
Variant_Options 9841.02305:
9841.02305|Yellow|Reel|305 m|8719605022813
View AllClose