Electronic, 2 Conductor 16AWG (Solid) Bare Copper, PVC Insulation, Overall Beldfoil® Shield, Red PVC Outer Jacket, FPLR
Specifications
Specifications
Product Overview
| Suitable Applications | fire alarms; indoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, …) |
|---|
Construction Details
Conductor
| Element | Number of Element | Size | Stranding | Material |
|---|---|---|---|---|
| Conductor(s) | 2 | 16 | Solid | BC - Bare Copper |
Insulation
| Material | Nom. Thickness | Nom. Insulation Diameter | Color Code |
|---|---|---|---|
| PVC - Polyvinyl Chloride | 0.016 in (0.41 mm) | 0.048 in (1.2 mm) | Black, Red |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|---|---|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 22 AWG (7x30) TC |
Outer Jacket
| Material | Nom. Thickness | Nom. Diameter |
|---|---|---|
| PVC - Polyvinyl Chloride | 0.036 in (0.91 mm) | 0.241 in (6.12 mm) |
Electrical Characteristics
Electricals
| Nom. Conductor DCR | Nom. Capacitance Cond-to-Cond | Nom. Capacitance Cond-to-Other (Conds + Shield) | Max. Current |
|---|---|---|---|
| 4.2 Ohm/1000ft | 57.5 pF/ft (189 pF/m) | 103.5 pF/ft (339.6 pF/m) | 11 Amps per Conductor at 25ºC |
Voltage
| UL Voltage Rating |
|---|
| 300 V |
Mechanical Characteristics
Temperature
| UL Temperature | Operating |
|---|---|
| 105°C | -40°C To +105°C |
Bend Radius
| Stationary Min. | Installation Min. |
|---|---|
| 3.61 in (91.7 mm) | 3.61 in (91.7 mm) |
| Max. Pull Tension | 80 lbs (36 kg) |
|---|---|
| Bulk Cable Weight | 34 lbs/1000ft |
Standards and Compliance
| Environmental Suitability | Outdoor |
|---|---|
| Flammability / Reaction to Fire | UL1666 Riser, FT4, IEC 60332-1-2 |
| CPR Compliance | CPR Euroclass: Eca |
| NEC / UL Compliance | Article 760, CMR, FPLR |
| AWM Compliance | AWM 2464 |
| CEC / C(UL) Compliance | FAS105 |
| European Directive Compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
| Other Standard Compliance(s) | California State Fire Marshall |
History
| Update and Revision | Revision Number: 0.529 Revision Date: 04-19-2023 |
|---|
Documentation
Product Bulletins
Compliance Documentation
Data Sheets
Additional Information
Variant_Options: |
Item #|Color|Putup Type|Length|UPC/EAN |
Variant_Options 9575 0025000: |
9575 0025000|Red|||612825256175 |
Variant_Options 9575 002U1000: |
9575 002U1000|Red|||612825256151 |
Variant_Options 9575 002U500: |
9575 002U500|Red|||612825256168 |
Variant_Options 9575.00U999: |
9575.00U999|Red|Flat Box|287 m|8719605022301 |
Variant_Options 9575.00305: |
9575.00305|Red|Reel|305 m|8719605022288 |
Variant_Options 9575.00U305: |
9575.00U305|Red|Flat Box|305 m|8719605022295 |
Variant_Options 9575.002000: |
9575.002000|Red|Reel|2,000 m|8719605022271 |