Belden

9581 - Electronic, 2 C #14 Sol BC, PVC Ins, OS, Red PVC Jkt, FPLR

(No reviews yet) Write a Review
SKU:
9581
Shipping:
Calculated at Checkout
$0.00

Description

Electronic, 2 Conductor 14AWG (Solid) Bare Copper, PVC Insulation, Overall Beldfoil® Shield, Red PVC Outer Jacket, FPLR

Specifications

Specifications

Product Overview

Suitable Applicationsfire alarms; indoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, …)

Construction Details

Conductor

ElementNumber of ElementSizeStrandingMaterial
Conductor(s)214SolidBC - Bare Copper

Insulation

MaterialNom. ThicknessNom. Insulation DiameterColor Code
PVC - Polyvinyl Chloride0.022 in (0.56 mm)0.20 in (5.1 mm)Black, Red

Outer Shield

Shield TypeMaterialCoverageDrainwire Type
TapeBi-Laminate (Alum+Poly)100%16 AWG (19x29) TC

Outer Jacket

MaterialNom. ThicknessNom. Diameter
PVC - Polyvinyl Chloride0.042 in (1.1 mm)0.306 in (7.77 mm)

Electrical Characteristics

Electricals

Nom. Conductor DCRNom. Capacitance Cond-to-CondNom. Capacitance Cond-to-Other (Conds + Shield)Max. Current
2.62 Ohm/1000ft55 pF/ft (180 pF/m)105 pF/ft (344 pF/m)18 Amps per Conductor at 25ºC

Voltage

UL Voltage Rating
300 V

Mechanical Characteristics

Temperature

UL TemperatureOperating
105°C-40°C To +105°C

Bend Radius

Stationary Min.Installation Min.
4.59 in (117 mm)4.59 in (117 mm)
Max. Pull Tension124 lbs (56.2 kg)
Bulk Cable Weight60 lbs/1000ft

Standards and Compliance

Environmental SuitabilityIndoor, Outdoor
Flammability / Reaction to FireUL1666 Riser, FT4, IEC 60332-1-2
CPR ComplianceCPR Euroclass: Eca
NEC / UL ComplianceArticle 760, FPLR
AWM ComplianceAWM 2464
CEC / C(UL) ComplianceFAS105
European Directive ComplianceEU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation ComplianceUKCA Mark
APAC ComplianceChina RoHS II (GB/T 26572-2011)
Other Standard Compliance(s)California State Fire Marshall

Product Notes

NotesThis cable passes the UL 1685 70,000 BTU Flame Test (comparable to the IEEE 383 Flame Test) and is listed by the California State Fire Marshall. Component Recognized UL 2464, 300V 80░C.

History

Update and RevisionRevision Number: 0.511 Revision Date: 01-20-2023

Documentation

Product Bulletins

Compliance Documentation

Data Sheets

View AllClose

Additional Information

Variant_Options:
Item #|Color|UPC
Variant_Options 9581 0021000:
9581 0021000|Red|612825256236
Variant_Options 9581 002U500:
9581 002U500|Red|612825256229
View AllClose