Belden

GIPTDD1 - Indoor tight buffered patchcord LSZH jacket 2.4mm simplex MM OM3.

(No reviews yet) Write a Review
SKU:
GIPTDD1
Shipping:
Calculated at Checkout
$0.00

Description

Indoor tight buffered patchcord with Low Smoke Zero Halogen outer jacket. 2.4mm simplex MM OM3.

Specifications

Specifications

Product Overview

Environmental SpaceIndoor (Not Riser or Plenum)
Suitable ApplicationsFlexible terminating leads such as pigtails, patchcords and test leads. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Short distance applications for indoor use.

Construction

Fiber Cable Construction

Fiber TypeFiber Count
OM31
Fiber Color CodingTIA coding (Gxxxxxx.T): Blue

Buffer Specification

Fiber TypeBuffer ConstructionBuffer MaterialBuffer Diameter
OM3TightLSZH - Low Smoke Zero Halogen (Flame Retardant)0.9 mm
Cable Core Water TightYes
Bulk Cable Weight5.6 kg/km

SubUnit Specifications

Fibers Per Subunit1

Jacket Specifications

Number of JacketsSingle Jacket
Type of ArmorNon-Armored

Outer Jacket Specifications

Outer Jacket

MaterialNominal DiameterRipcord
LSZH - Low Smoke Zero Halogen (Flame Retardant)2.4 mmNo
Table NotesStandard color: Orange. Available colors: Orange, Yellow, Turquoise, Erika Violet, Red, Blue, Green, Brown, Violet, Pink, Grey, White, Black, Lime Green

Optical Characteristics

Max. Attenuation at 1300 nm0.9 dB/km
Max. Attenuation at 850 nm2.9 dB/km

Mechanical Characteristics

Mechanical Tests

DescriptionTested StandardRequirement/ValueAccording to Family Specification
Cable Min. Bend Radius Operation (Long Term)IEC 60794-1-21-E1160 mmIEC 60794-2-10
Cable Max. Tensile Strength Installation (Short Term)IEC 60794-1-21-E1300 N (67 lbf)IEC 60794-2-10
Cable Max. Tensile Strength Operation (Long Term)IEC 60794-1-21-E1100 N (22 lbf)IEC 60794-2-10
Cable Max. Crush Resistance Installation (Short Term)IEC 60794-1-21-E35 kN/mIEC 60794-2-10

Temperature Range

Operating Temperature Range-40 °C to +70 °C
Installation Temperature Range-15 °C to +50 °C
Storage Temperature Range-40 °C to +70 °C

Standards

UL Rating/Flame TestNon-UL Rated
IEC FlammabilityIEC 60332-1-2
Reaction to Fire - Bundle Flame TestIEC 60332-1
IEC 60754-1 - Halogen AmountZero
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity10 µS/mm
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH4.3
IEC 61034-2 - Smoke Density Min. Transmittance60%
REACHCompliant
ISO/IEC ComplianceIEC 60794
UV/ Sunlight ProtectionYes

History

Update and RevisionRevision Number: 0.76 Revision Date: 01-20-2023
View AllClose