Belden

HP142412 - Inst, 24 Pr #14 Str BC, PVC Ins E1, OS, Blk PVC Jkt, 300V PLTC SUN RES

(No reviews yet) Write a Review
SKU:
HP142412
Shipping:
Calculated at Checkout
$0.00

Description

UL Instrumentation, 24 Pair 14AWG (7x22) Bare Copper, PVC Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, PLTC SUN RES

Specifications

Specifications

Put-Up TypeReel

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNo. of Pairs
147x22BC - Bare Copper24
Conductor Count48

Insulation

MaterialNominal Diameter
PVC - Polyvinyl Chloride0.114 in

Color Chart

NumberColor
1Black & White and Numbered 1
2Black & White and Numbered 2
3Black & White and Numbered 3
4Black & White and Numbered 4
5Black & White and Numbered 5
6Black & White and Numbered 6
7Black & White and Numbered 7
8Black & White and Numbered 8
9Black & White and Numbered 9
10Black & White and Numbered 10
11Black & White and Numbered 11
12Black & White and Numbered 12
13Black & White and Numbered 13
14Black & White and Numbered 14
15Black & White and Numbered 15
16Black & White and Numbered 16
17Black & White and Numbered 17
18Black & White and Numbered 18
19Black & White and Numbered 19
20Black & White and Numbered 20
21Black & White and Numbered 21
22Black & White and Numbered 22
23Black & White and Numbered 23
24Black & White and Numbered 24

Outer Shield

TypeMaterialMaterial Trade NameCoverage [%]Drainwire MaterialDrainwire AWG
TapeBi-Laminate (Alum+Poly)Beldfoil®100%TC - Tinned Copper14

Outer Jacket

MaterialNominal DiameterNominal Wall Thickness
PVC - Polyvinyl Chloride1.313 in0.085 in

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR
2.52 Ohm/1000ft

Voltage

UL Voltage Rating
300 V RMS

Temperature Range

Operating Temperature Range-30°C To +105°C

Mechanical Characteristics

UV ResistanceYes
Bulk Cable Weight1049 lbs/1000ft
Max. Pull Tension1546 lbs
Min Bend Radius (Overall)13.1 in

Standards

NEC/(UL) CompliancePLTC-ER

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
EU CE MarkYes
CA Prop 65Yes

Suitability

Suitability - BurialNo
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityUL 1685 UL Loading
UL voltage rating300 V RMS

Plenum/Non-Plenum

Plenum (Y/N)No

History

Update and RevisionRevision Number: 0.38 Revision Date: 04-08-2022
View AllClose