Belden

IEA001 - DataTuff® 6A, 4 Bonded-Pr #23 Sol BC, PO Ins, PVC Jkt, CMR

(No reviews yet) Write a Review
SKU:
IEA001
Shipping:
Calculated at Checkout
$0.00

Description

4 Bonded-Pair, U/UTP-Unshielded, Category 6A, Riser, 23 AWG Solid Bare Copper, PO Insulation, Patented X-Spline & EquiBlock™ Technologies, PVC Jacket, Sequential Markings at 2 Feet

Specifications

Specifications

Product Overview

Suitable Applicationsexposure to oil and gasoline, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc.
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details

Conductor

SizeStrandingMaterialNumber of Pairs
23SolidBC - Bare Copper4

Insulation

MaterialColor Code
PO - PolyolefinWhite & Blue, White & Orange, White & Green, White & Brown
Bonded-PairYes

Outer Jacket

SeparatorMaterialNom. DiameterRipcord
Center Member (Patented X-Spline®), EquiBlock™ Barrier TechnologyPVC - Polyvinyl Chloride0.305 in (7.75 mm)Yes
Overall Cable Diameter (Nominal)0.305 in (7.75 mm)

Electrical Characteristics

Electricals

Max. Conductor DCRMax. Capacitance Unbalance
82 Ohm/km (25 Ohm/1000ft)45 pF/100m

Delay

FrequencyMax. DelayMax. Delay SkewNom. Velocity of Prop.
100 MHz537.6 ns/100m45 ns/100m65%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted)Max./Min. Fitted ImpedanceMin. PSANEXT [dB]Min. PSAACRF [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.1 dB/100m74.372.372.270.267.864.820.0105 +/- 10115 +/- 1567.067.040.035.0
43.8 dB/100m65.363.361.559.555.852.823.0105 +/- 10100 +/- 767.066.240.023.0
85.3 dB/100m60.858.855.453.449.746.724.5100 +/- 22100 +/- 767.060.140.016.9
105.9 dB/100m59.357.353.451.447.844.825.0100 +/- 22100 +/- 767.058.240.015.0
167.5 dB/100m56.254.248.846.843.740.725.0100 +/- 22100 +/- 767.054.138.010.9
208.4 dB/100m54.852.846.444.441.838.825.0100 +/- 22100 +/- 767.052.237.09.0
259.4 dB/100m53.351.344.042.039.836.824.3100 +/- 22100 +/- 767.050.236.07.0
31.2510.5 dB/100m51.949.941.439.437.934.923.6100 +/- 22100 +/- 767.048.335.15.1
62.515.0 dB/100m47.445.432.430.431.928.921.5100 +/- 22100 +/- 765.642.332.0
10019.1 dB/100m44.342.325.223.227.824.820.1100 +/- 22100 +/- 762.538.230.0
20027.6 dB/100m39.837.812.210.221.818.818.0100 +/- 22100 +/- 758.032.227.0
25031.1 dB/100m38.336.37.35.319.816.817.3100 +/- 32100 +/- 756.530.226.0
30034.3 dB/100m37.135.12.90.918.315.316.8100 +/- 32100 +/- 755.328.725.2
35037.2 dB/100m36.134.116.913.916.3100 +/- 32100 +/- 754.327.324.6
40040.1 dB/100m35.333.315.812.815.9100 +/- 32100 +/- 753.526.224.0
45042.7 dB/100m34.532.514.711.715.5100 +/- 32100 +/- 752.725.123.5
50045.3 dB/100m33.831.813.810.815.2100 +/- 32100 +/- 752.024.223.0

Voltage

UL Voltage Rating
300 V (CMR)

Mechanical Characteristics

Temperature

UL TemperatureOperatingInstallationStorage
75°C-40°C To +75°C-40°C To +60°C-40°C To +75°C

Bend Radius

Installation Min.
3.5 in (89 mm)
Max. Pull Tension40 lbs (18 kg)
Bulk Cable Weight39 lbs/1000ft

Standards and Compliance

Environmental SuitabilityRiser, Indoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / Reaction to FireUL 1666 Riser
CPR ComplianceCPR Euroclass: Fca
NEC / UL ComplianceCMR
CEC / C(UL) ComplianceCMR
ICEA ComplianceS-116-732, S-56-434, S-99-689, S-100-685
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA ComplianceANSI/NEMA WC-66
Data CategoryCategory 6A
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6A
ISO/IEC ComplianceISO/IEC 11801-1, IEC 61156-5
CENELEC ComplianceSegregation class according EN50174-2 = a
European Directive ComplianceEU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC ComplianceChina RoHS II (GB/T 26572-2011)

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial. Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1.

History

Update and RevisionRevision Number: 0.157 Revision Date: 01-20-2023
View AllClose