Belden

IEA002 - DataTuff® 6A, 4 Bonded-Pr #23 Sol BC, PO Ins, OS, PVC Jkt, CMR

(No reviews yet) Write a Review
SKU:
IEA002
Shipping:
Calculated at Checkout
$0.00

Description

4 Bonded-Pair, F/UTP, Category 6A, Riser, 23 AWG Solid Bare Copper, PO Insulation, Patented X-Spline™ Technology, Overall Beldfoil® Shield, PVC Jacket, Sequential Markings at 2 Feet

Specifications

Specifications

Product Overview

Suitable Applicationsexposure to oil and gasoline, harsh environment, IIoT, factory or process automation, IP cameras and devices, data communication, etc.
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Physical Characteristics (Overall)

Conductor

AWGStrandingMaterialNo. of Pairs
23SolidBC - Bare Copper4

Insulation

Material
PO - Polyolefin
Bonded-PairYes

Color Chart

Color
White & Blue
White & Orange
White & Green
White & Brown

Outer Shield

TypeMaterialCoverage [%]
TapePolyester + Bi-Laminate (Alum+Poly)100%

Outer Jacket

MaterialNominal DiameterRipcordSeparator Material
PVC - Polyvinyl Chloride0.311 inYesCenter Member (Patented X-Spline®)

Electrical Characteristics

Conductor DCR

Max. Conductor DCRMax. DCR UnbalanceMax DCR Unbalanced Between Pairs [%]
82 Ohm/km3 %5 %

Capacitance

Max. Capacitance UnbalanceNom.Mutual Capacitance
45 pF/100m17 pF/ft

Delay

Frequency [MHz]Max. DelayMax. Delay SkewNominal Velocity of Propagation (VP) [%]
100 MHz537.6 ns/100m45 ns/100m65%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation)Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted)Max./Min. Fitted ImpedanceMin. PSANEXTMin. PSAACRFMin. TCL [dB]Min. ELTCTL [dB]
1 MHz2.1 dB/100m74.3 dB72.3 dB72.2 dB70.2 dB67.8 dB64.8 dB20.0 dB105 +/- 10115 +/- 1567.0 dB67.0 dB40.0 dB35.0 dB
4 MHz3.8 dB/100m65.3 dB63.3 dB61.5 dB59.5 dB55.8 dB52.8 dB23.0 dB105 +/- 10100 +/- 767.0 dB66.2 dB40.0 dB23.0 dB
8 MHz5.3 dB/100m60.8 dB58.8 dB55.4 dB53.4 dB49.7 dB46.7 dB24.5 dB100 +/- 22100 +/- 767.0 dB60.1 dB40.0 dB16.9 dB
10 MHz5.9 dB/100m59.3 dB57.3 dB53.4 dB51.4 dB47.8 dB44.8 dB25.0 dB100 +/- 22100 +/- 767.0 dB58.2 dB40.0 dB15.0 dB
16 MHz7.5 dB/100m56.2 dB54.2 dB48.8 dB46.8 dB43.7 dB40.7 dB25.0 dB100 +/- 22100 +/- 767.0 dB54.1 dB38.0 dB10.9 dB
20 MHz8.4 dB/100m54.8 dB52.8 dB46.4 dB44.4 dB41.8 dB38.8 dB25.0 dB100 +/- 22100 +/- 767.0 dB52.2 dB37.0 dB9.0 dB
25 MHz9.4 dB/100m53.3 dB51.3 dB44.0 dB42.0 dB39.8 dB36.8 dB24.3 dB100 +/- 22100 +/- 767.0 dB50.2 dB36.0 dB7.0 dB
31.25 MHz10.5 dB/100m51.9 dB49.9 dB41.4 dB39.4 dB37.9 dB34.9 dB23.6 dB100 +/- 22100 +/- 767.0 dB48.3 dB35.1 dB5.1 dB
62.5 MHz15.0 dB/100m47.4 dB45.4 dB32.4 dB30.4 dB31.9 dB28.9 dB21.5 dB100 +/- 22100 +/- 765.6 dB42.3 dB32.0 dB
100 MHz19.1 dB/100m44.3 dB42.3 dB25.2 dB23.2 dB27.8 dB24.8 dB20.1 dB100 +/- 22100 +/- 762.5 dB38.2 dB30.0 dB
200 MHz27.6 dB/100m39.8 dB37.8 dB12.2 dB10.2 dB21.8 dB18.8 dB18.0 dB100 +/- 22100 +/- 758.0 dB32.2 dB27.0 dB
250 MHz31.1 dB/100m38.3 dB36.3 dB7.3 dB5.3 dB19.8 dB16.8 dB17.3 dB100 +/- 32100 +/- 756.5 dB30.2 dB26.0 dB
300 MHz34.3 dB/100m37.1 dB35.1 dB2.9 dB0.9 dB18.3 dB15.3 dB16.8 dB100 +/- 32100 +/- 755.3 dB28.7 dB25.2 dB
350 MHz37.2 dB/100m36.1 dB34.1 dB16.9 dB13.9 dB16.3 dB100 +/- 32100 +/- 754.3 dB27.3 dB24.6 dB
400 MHz40.1 dB/100m35.3 dB33.3 dB15.8 dB12.8 dB15.9 dB100 +/- 32100 +/- 753.5 dB26.2 dB24.0 dB
450 MHz42.7 dB/100m34.5 dB32.5 dB14.7 dB11.7 dB15.5 dB100 +/- 32100 +/- 752.7 dB25.1 dB23.5 dB
500 MHz45.3 dB/100m33.8 dB31.8 dB13.8 dB10.8 dB15.2 dB100 +/- 32100 +/- 752.0 dB24.2 dB23.0 dB
Segregation class according EN50174-2a

Voltage

Non-UL Voltage Rating
300 V

Temperature Range

Installation Temperature Range-40°C To +60°C
Storage Temperature Range-40°C To +75°C
Operating Temperature Range-40°C To +75°C

Mechanical Characteristics

UV ResistanceYes
Bulk Cable Weight41 lbs/1000ft
Max. Pull Tension40 lbs
Min. Bend Radius During Installation3.5 in

Standards

UL AWM Style ComplianceAWM 21137 (600V)
ISO/IEC ComplianceISO/IEC 11801-1, IEC 61156-5
CPR EuroclassFca
Data CategoryCategory 6A
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6A
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA ComplianceANSI/NEMA WC-66

Applicable Environmental and Other Programs

Environmental SpaceIndoor/Outdoor
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU CE MarkNo
EU REACH SVHC Compliance (yyyy-mm-dd)2020-01-16
MII Order #39 (China RoHS)Yes

Suitability

Suitability - AerialNo
Suitability - BurialNo
Suitability - Hazardous LocationsNo
Suitability - IndoorYes
Suitability - Non-HalogenatedNo
Suitability - Oil ResistanceYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

UL FlammabilityCMR

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial. Belden recommends using an entrance demarcation point when transitioning inside buildings with gel-filled OSP cables due to the cable design containing gel specific for wet outdoor environments. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1.

History

Update and RevisionRevision Number: 0.147 Revision Date: 07-19-2023
View AllClose