Category 6A Premise Horizontal Cable, Indoor/Outdoor, 4 Pair, 23 AWG Solid Bare Copper Conductors, F/UTP - Foil Shielded, Plenum-CMP/CMX Oudoor, Gel Free
Specifications
Specifications
Product Overview
| Suitable Applications | Indoor/Outdoor, Premise Horizontal Cable, Ethernet up to 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, Noisy Enivronments, HDBaseT, IP Cameras, Wet Locations following Product Notes |
|---|
| Patent | This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents. |
|---|
Construction Details
Conductor
| Size | Stranding | Material | Number of Pairs |
|---|
| 23 | Solid | BC - Bare Copper | 4 |
Insulation
| Material | Color Code |
|---|
| FEP - Fluorinated Ethylene Propylene | White & Blue, White & Orange, White & Green, White & Brown |
Outer Shield
| Shield Type | Material | Coverage | Drainwire Type |
|---|
| Tape | Bi-Laminate (Alum+Poly) | 100% | 26 AWG (7x34) TC |
Outer Jacket
| Separator | Material | Nom. Diameter | Ripcord |
|---|
| Center Member (Patented X-Spline®) | PVDF - Polyvinylidene Fluoride | 0.27 in (6.9 mm) | Yes |
| Overall Cable Diameter (Nominal) | 0.27 in (6.9 mm) |
|---|
Electrical Characteristics
Electricals
| Max. Conductor DCR | Max. Capacitance Unbalance |
|---|
| 82 Ohm/km (25 Ohm/1000ft) | 45 pF/100m |
Delay
| Frequency | Max. Delay | Max. Delay Skew | Nom. Velocity of Prop. |
|---|
| 100 MHz | 537.6 ns/100m | 45 ns/100m | 70% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) [dB/100m] | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Max./Min. Input Impedance (unFitted) | Max./Min. Fitted Impedance | Min. PSANEXT [dB] | Min. PSAACRF [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
|---|
| 1 | 2.1 | 74.3 | 72.3 | 72.2 | 70.2 | 67.8 | 64.8 | 20.0 | 105 +/- 10 | 115 +/- 15 | 67.0 | 67.0 | 40.0 | 35.0 |
| 4 | 3.8 | 65.3 | 63.3 | 61.5 | 59.5 | 55.8 | 52.8 | 23.0 | 105 +/- 10 | 100 +/- 7 | 67.0 | 66.2 | 40.0 | 23.0 |
| 8 | 5.3 | 60.8 | 58.8 | 55.4 | 53.4 | 49.7 | 46.7 | 24.5 | 100 +/- 22 | 100 +/- 7 | 67.0 | 60.1 | 40.0 | 16.9 |
| 10 | 5.9 | 59.3 | 57.3 | 53.4 | 51.4 | 47.8 | 44.8 | 25.0 | 100 +/- 22 | 100 +/- 7 | 67.0 | 58.2 | 40.0 | 15.0 |
| 16 | 7.5 | 56.2 | 54.2 | 48.8 | 46.8 | 43.7 | 40.7 | 25.0 | 100 +/- 22 | 100 +/- 7 | 67.0 | 54.1 | 38.0 | 10.9 |
| 20 | 8.4 | 54.8 | 52.8 | 46.4 | 44.4 | 41.8 | 38.8 | 25.0 | 100 +/- 22 | 100 +/- 7 | 67.0 | 52.2 | 37.0 | 9.0 |
| 25 | 9.4 | 53.3 | 51.3 | 44.0 | 42.0 | 39.8 | 36.8 | 24.3 | 100 +/- 22 | 100 +/- 7 | 67.0 | 50.2 | 36.0 | 7.0 |
| 31.25 | 10.5 | 51.9 | 49.9 | 41.4 | 39.4 | 37.9 | 34.9 | 23.6 | 100 +/- 22 | 100 +/- 7 | 67.0 | 48.3 | 35.1 | 5.1 |
| 62.5 | 15.0 | 47.4 | 45.4 | 32.4 | 30.4 | 31.9 | 28.9 | 21.5 | 100 +/- 22 | 100 +/- 7 | 65.6 | 42.3 | 32.0 | |
| 100 | 19.1 | 44.3 | 42.3 | 25.2 | 23.2 | 27.8 | 24.8 | 20.1 | 100 +/- 22 | 100 +/- 7 | 62.5 | 38.2 | 30.0 | |
| 200 | 27.6 | 39.8 | 37.8 | 12.2 | 10.2 | 21.8 | 18.8 | 18.0 | 100 +/- 22 | 100 +/- 7 | 58.0 | 32.2 | 27.0 | |
| 250 | 31.1 | 38.3 | 36.3 | 7.3 | 5.3 | 19.8 | 16.8 | 17.3 | 100 +/- 32 | 100 +/- 7 | 56.5 | 30.2 | 26.0 | |
| 300 | 34.3 | 37.1 | 35.1 | 2.9 | 0.9 | 18.3 | 15.3 | 16.8 | 100 +/- 32 | 100 +/- 7 | 55.3 | 28.7 | 25.2 | |
| 350 | 37.2 | 36.1 | 34.1 | | | 16.9 | 13.9 | 16.3 | 100 +/- 32 | 100 +/- 7 | 54.3 | 27.3 | 24.6 | |
| 400 | 40.1 | 35.3 | 33.3 | | | 15.8 | 12.8 | 15.9 | 100 +/- 32 | 100 +/- 7 | 53.5 | 26.2 | 24.0 | |
| 450 | 42.7 | 34.5 | 32.5 | | | 14.7 | 11.7 | 15.5 | 100 +/- 32 | 100 +/- 7 | 52.7 | 25.1 | 23.5 | |
| 500 | 45.3 | 33.8 | 31.8 | | | 13.8 | 10.8 | 15.2 | 100 +/- 32 | 100 +/- 7 | 52.0 | 24.2 | 23.0 | |
Voltage
| UL Voltage Rating |
|---|
| 300 V (CMP), 300 V (CL3P) |
Mechanical Characteristics
Temperature
| UL Temperature | Operating | Installation | Storage |
|---|
| 150C | -40°C To +75°C | 0°C To +60°C | -40°C To +75°C |
Bend Radius
| Installation Min. |
|---|
| 2.7 in (69 mm) |
| Max. Pull Tension | 25 lbs (11 kg) |
|---|
| Bulk Cable Weight | 39 lbs/1000ft (58 kg/km) |
|---|
Standards and Compliance
| Environmental Suitability | Indoor/Outdoor, Water Exposure/Below-Grade Conduit, Indoor, Outdoor, Sunlight Resistance |
|---|
| Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), FT6 |
|---|
| NEC / UL Compliance | Article 800, CMP |
|---|
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
|---|
| Data Category | Category 6A |
|---|
| TIA/EIA Compliance | ANSI/TIA-568.2-D Category 6A |
|---|
| ISO/IEC Compliance | 11801 ed 2.2 (2011) Class EA |
|---|
| CENELEC Compliance | Segregation class according EN50174-2 = a |
|---|
Product Notes
| Notes | Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial.
Cable jacket system is specially designed to protect cable core. Cable contains no water-blocking tapes, gels, or powders. Install in accordance with all applicable electrical codes. Maintain jacket integrity throughout installation process. Do not allow water or fluids to penetrate jacket sheath or to enter ends of cable. Ensure ends of cable will be protected from water/fluids after installation. |
|---|
History
| Update and Revision | Revision Number: 0.17 Revision Date: 04-19-2023 |
|---|