Belden

IOP6U - Category 6 Indoor/Outdoor Cable, 4 Pair, U/UTP, CMP/CMX, Gel Free

(No reviews yet) Write a Review
SKU:
IOP6U
Shipping:
Calculated at Checkout
$0.00

Description

Category 6 Premise Horizontal Cable, Indoor/Outdoor, 4 Pair, 23 AWG Solid Bare Copper Conductors, U/UTP, Plenum-CMP/CMX Oudoor, Gel Free

Specifications

Specifications

Product Overview

Suitable ApplicationsIndoor/Outdoor, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Wet Locations following Product Notes
PatentThis product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details

Conductor

SizeStrandingMaterialNumber of Pairs
23SolidBC - Bare Copper4

Insulation

MaterialColor Code
FEP - Fluorinated Ethylene PropyleneWhite & Blue, White & Orange, White & Green, White & Brown

Inner Jacket

SeparatorMaterialNom. DiameterRipcord
Barrier TapeThermoplastic0.270 in (6.86 mm)No

Outer Jacket

SeparatorMaterialNom. DiameterRipcord
Center Member (Patented X-Spline®), EquiBlock™ Barrier TechnologyPVDF - Polyvinylidene Fluoride0.27 in (6.9 mm)Yes
Overall Cable Diameter (Nominal)0.27 in (6.9 mm)

Electrical Characteristics

Electricals

Max. Conductor DCRMax. Capacitance Unbalance
82 Ohm/km (25 Ohm/1000ft)45 pF/100m

Delay

FrequencyMax. DelayMax. Delay SkewNom. Velocity of Prop.
100 MHz537.6 ns/100m45 ns/100m70%

High Frequency

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted)Max./Min. Fitted ImpedanceMin. PSANEXT [dB]Min. PSAACRF [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.174.372.372.270.267.864.820.0105 +/- 10115 +/- 1567.067.040.035.0
43.865.363.361.559.555.852.823.0105 +/- 10100 +/- 767.066.240.023.0
85.360.858.855.453.449.746.724.5100 +/- 22100 +/- 767.060.140.016.9
105.959.357.353.451.447.844.825.0100 +/- 22100 +/- 767.058.240.015.0
167.556.254.248.846.843.740.725.0100 +/- 22100 +/- 767.054.138.010.9
208.454.852.846.444.441.838.825.0100 +/- 22100 +/- 767.052.237.09.0
259.453.351.344.042.039.836.824.3100 +/- 22100 +/- 767.050.236.07.0
31.2510.551.949.941.439.437.934.923.6100 +/- 22100 +/- 767.048.335.15.1
62.515.047.445.432.430.431.928.921.5100 +/- 22100 +/- 765.642.332.0
10019.144.342.325.223.227.824.820.1100 +/- 22100 +/- 762.538.230.0
20027.639.837.812.210.221.818.818.0100 +/- 22100 +/- 758.032.227.0
25031.138.336.37.35.319.816.817.3100 +/- 32100 +/- 756.530.226.0
30034.337.135.12.90.918.315.316.8100 +/- 32100 +/- 755.328.725.2
35037.236.134.116.913.916.3100 +/- 32100 +/- 754.327.324.6
40040.135.333.315.812.815.9100 +/- 32100 +/- 753.526.224.0
45042.734.532.514.711.715.5100 +/- 32100 +/- 752.725.123.5
50045.333.831.813.810.815.2100 +/- 32100 +/- 752.024.223.0

Voltage

UL Voltage Rating
300 V (CMP), 300 V (CL3P)

Mechanical Characteristics

Temperature

UL TemperatureOperatingInstallationStorage
150C-40°C To +75°C0°C To +60°C-40°C To +75°C

Bend Radius

Installation Min.
2.7 in (69 mm)
Max. Pull Tension25 lbs (11 kg)
Bulk Cable Weight39 lbs/1000ft (58 kg/km)

Standards and Compliance

Environmental SuitabilityIndoor/Outdoor, Water Exposure/Below-Grade Conduit, Indoor, Outdoor, Sunlight Resistance
Flammability / Reaction to FireNFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2
NEC / UL ComplianceArticle 800, CMP
CEC / C(UL) ComplianceCMP
ICEA ComplianceS-116-732
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
NEMA ComplianceANSI/NEMA WC-66
Data CategoryCategory 6
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6
Third Party Performance VerificationCategory 6
ISO/IEC Compliance11801 ed 2.2 (2011) Class EA
CENELEC ComplianceSegregation class according EN50174-2 = a

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial. Cable jacket system is specially designed to protect cable core. Cable contains no water-blocking tapes, gels, or powders. Install in accordance with all applicable electrical codes. Maintain jacket integrity throughout installation process. Do not allow water or fluids to penetrate jacket sheath or to enter ends of cable. Ensure ends of cable will be protected from water/fluids after installation.

History

Update and RevisionRevision Number: 0.35 Revision Date: 04-19-2023
View AllClose

Additional Information

Variant_Options:
Item #|Color|Putup Type|Length
Variant_Options IOP6U 0101000:
IOP6U 0101000|Black|Reel|1,000 ft
View AllClose