Marine Ethernet Cat 6A Cable, 4 Pr 23AWG Annealed Bare Copper, Foam Polyethylene Insulation, U/FTP, Low Smoke Zero Halogen (SHF1) Jacket, Indoor Shipboard, LR certified
Specifications
Specifications
Product Overview
Suitable Applications | Shipbuilding, in-cabin passenger Wi-Fi, high-bandwidth IPTV, PoE lighting, device charging stations, onboard security cameras, etc. |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
23 | Solid | BC - Bare Copper | 4 |
Conductor Count | 8 |
---|
Total Number of Pairs | 4 |
---|
Insulation
Material | Nominal Diameter |
---|
PO - Polyolefin (Foam) | 1.35 mm |
Color Chart
Number | Color |
---|
Pair 1 | White & Blue |
Pair 2 | White & Orange |
Pair 3 | White & Green |
Pair 4 | White & Brown |
Inner Shield
Type | Material |
---|
Tape | Bi-Laminate (Alum+Poly) |
Outer Shield
Drainwire Material | Drainwire AWG |
---|
Tinned Copper | 28 AWG |
Outer Jacket
Material | Nominal Diameter | Diameter +/- Tolerance |
---|
LSZH - Low Smoke Zero Halogen (SHF1) | 7.5 mm | 0.3 mm |
Construction and Dimensions
Min Elongation at Breakof Jacket | 125 % |
---|
Min Tensile Strength of Jacket | 9 MPa |
---|
Min Tensile Strength of Jacket Aged | 30 % |
---|
Min Elongation at Break of Jacket Aged | 30 % |
---|
Electrical Characteristics
Conductor DCR
Max. Conductor DCR | Max DCR Unbalanced Between Pairs [%] | Max. DCR Unbalanced Within Pair [%] |
---|
95 Ohm/km | 4 % | 2 % |
Capacitance
Max. Capacitance Unbalance | Max. Mutual Capacitance |
---|
160 pF/100m | 56 pF/m |
Insulation Resistance | 5000 MOhm.m |
---|
Impedance
Nominal Characteristic Impedance |
---|
100 Ohm |
Delay
Max. Delay Skew | Nominal Velocity of Propagation (VP) [%] |
---|
45 ns/100m | 77% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. PSANEXT | Min. PSAACRF | Min. TCL [dB] | Min. ELTCTL [dB] |
---|
1 MHz | 2.1 dB/100m | 75.3 dB | 72.3 dB | 73.2 dB | 70.2 dB | 68 dB | 65 dB | 20 dB | 67 dB | 67 dB | 40 dB | 35 dB |
4 MHz | 3.8 dB/100m | 66.3 dB | 63.3 dB | 62.5 dB | 59.5 dB | 56 dB | 53 dB | 23 dB | 67 dB | 66.2 dB | 34 dB | 23 dB |
10 MHz | 5.9 dB/100m | 60.3 dB | 57.3 dB | 54.4 dB | 51.4 dB | 48 dB | 45 dB | 25 dB | 67 dB | 58.2 dB | 30 dB | 15 dB |
16 MHz | 7.5 dB/100m | 57.2 dB | 54.2 dB | 49.7 dB | 46.7 dB | 43.9 dB | 40.9 dB | 25 dB | 67 dB | 54.1 dB | 28 dB | 10.9 dB |
31.3 MHz | 10.5 dB/100m | 52.9 dB | 49.9 dB | 42.4 dB | 39.4 dB | 38.1 dB | 35.1 dB | 23.6 dB | 67 dB | 48.3 dB | 25.1 dB | 5.1 dB |
62.5 MHz | 15.0 dB/100m | 48.4 dB | 45.4 dB | 33.4 dB | 30.4 dB | 32.1 dB | 29.1 dB | 21.5 dB | 65.6 dB | 42.3 dB | 22 dB | |
100 MHz | 19.1 dB/100m | 45.3 dB | 42.3 dB | 26.2 dB | 23.2 dB | 28 dB | 25 dB | 20.1 dB | 62.5 dB | 38.2 dB | 20 dB | |
125 MHz | 21.5 dB/100m | 43.8 dB | 40.8 dB | 22.3 dB | 19.3 dB | 26.1 dB | 23.1 dB | 19.4 dB | 61 dB | 36.3 dB | 19 dB | |
200 MHz | 27.6 dB/100m | 40.8 dB | 37.8 dB | 13.2 dB | 10.2 dB | 22 dB | 19 dB | 18 dB | 58 dB | 32.2 dB | 17 dB | |
250 MHz | 31.1 dB/100m | 39.3 dB | 36.3 dB | 8.2 dB | 5.2 dB | 20 dB | 17 dB | 17.3 dB | 56.5 dB | 30.2 dB | 16 dB | |
350 MHz | 34.3 dB/100m | 37.1 dB | 34.1 dB | | | 17.1 dB | 14.1 dB | 17.3 dB | 54.3 dB | 27.3 dB | | |
500 MHz | 45.3 dB/100m | 34.8 dB | 31.8 dB | | | 14 dB | 11 dB | 17.3 dB | 52 dB | 24.2 dB | | |
Table Notes | Limits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009) |
---|
Coupling Attenuation Class | Type Ib |
---|
Transfer Impedance Class | Grade 2 |
---|
Voltage
Voltage Rating [V] |
---|
72 V DC |
Temperature Range
Installation Temperature Range | -5°C To +80°C |
---|
Operating Temperature Range | -40°C To +80°C |
---|
Mechanical Characteristics
Bending Test | Low temperature bending test -40 °C : No cracks |
---|
Pressure Test for Jacket | Test at high temperature IEC 60811-508 80±2 °C 4h : ≤ 50 % |
---|
Heat Stroke Test | Heat Shock test at (150±3°C ,1h) : No cracks |
---|
Bulk Cable Weight | 57.3 kg/km |
---|
Min. Bend Radius During Installation | 10*D |
---|
Standards
ISO/IEC Compliance | ISO/IEC 11801-2, IEC 60092-360 |
---|
CENELEC Compliance | EN 50173-1 |
---|
Data Category | Category 6A |
---|
ANSI Compliance | ANSI/TIA 568.2-D (2018) |
---|
IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor |
---|
Suitability
Flammability, LS0H, Toxicity Testing
IEC Flammability | IEC 60332-1-2, IEC 60332-3-22 |
---|
Fluorine Content Test IEC60684-2 | HF ≤ 0.1% |
---|
IEC 60754-1 - Halogen Amount | HCL+HBr ≤ 0.5% |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 10 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
---|
Product Notes
Footnote | *Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length. |
---|
Notes | LR (Lloyd’s Register) certification |
---|
History
Update and Revision | Revision Number: 0.27 Revision Date: 11-09-2022 |
---|