Marine Ethernet Cat 7, 4 Pr 23AWG Annealed Bare Copper, Foam Polyethylene Insulation, S/FTP, Low Smoke Zero Halogen (SHF1) Jacket, Indoor Shipboard, LR certified
Specifications
Specifications
Product Overview
Suitable Applications | Shipbuilding, in-cabin passenger Wi-Fi, high-bandwidth IPTV, PoE lighting, device charging stations, onboard security cameras, etc. |
---|
Physical Characteristics (Overall)
Conductor
AWG | Stranding | Material | No. of Pairs |
---|
23 | Solid | BC - Bare Copper | 4 |
Conductor Count | 8 |
---|
Total Number of Pairs | 4 |
---|
Insulation
Material | Nominal Diameter |
---|
PO - Polyolefin (Foam) | 1.35 mm |
Color Chart
Number | Color |
---|
Pair 1 | White & Blue |
Pair 2 | White & Orange |
Pair 3 | White & Green |
Pair 4 | White & Brown |
Inner Shield
Element | Type | Material | Coverage [%] |
---|
Individual Shielded Pair | Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Shield
Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG |
---|
Braid | Tinned Copper (TC) | 30% | Tinned Copper | 28 AWG |
Outer Jacket
Material | Nominal Diameter | Diameter +/- Tolerance |
---|
LSZH - Low Smoke Zero Halogen (SHF1) | 7.8 mm | 0.3 mm |
Construction and Dimensions
Min Elongation at Breakof Jacket | 125 % |
---|
Min Tensile Strength of Jacket | 9 MPa |
---|
Min Tensile Strength of Jacket Aged | 30 % |
---|
Min Elongation at Break of Jacket Aged | 30 % |
---|
Electrical Characteristics
Conductor DCR
Max. Conductor DCR | Max DCR Unbalanced Between Pairs [%] | Max. DCR Unbalanced Within Pair [%] |
---|
95 Ohm/km | 4 % | 2 % |
Capacitance
Max. Capacitance Unbalance | Max. Mutual Capacitance |
---|
160 pF/100m | 56 pF/m |
Insulation Resistance | 5000 MOhm.m |
---|
Impedance
Nominal Characteristic Impedance |
---|
100 Ohm |
Delay
Max. Delay Skew | Nominal Velocity of Propagation (VP) [%] |
---|
25 ns/100m | 78% |
High Frequency
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
---|
1 MHz | 2.1 dB/100m | 78 dB | 75 dB | 75.9 dB | 72.9 dB | 78 dB | 75 dB | 20 dB | 40 dB | 35 dB |
4 MHz | 3.7 dB/100m | 78 dB | 75 dB | 74.3 dB | 71.3 dB | 78 dB | 75 dB | 23 dB | 34 dB | 23 dB |
10 MHz | 5.8 dB/100m | 78 dB | 75 dB | 72.2 dB | 69.2 dB | 74 dB | 71 dB | 25 dB | 30 dB | 15 dB |
16 MHz | 7.3 dB/100m | 78 dB | 75 dB | 70.7 dB | 67.7 dB | 69.9 dB | 66.9 dB | 25 dB | 28 dB | 10.9 dB |
31.3 MHz | 10.3 dB/100m | 78 dB | 75 dB | 67.7 dB | 64.7 dB | 64.1 dB | 61.1 dB | 23.6 dB | 25.1 dB | 5.1 dB |
62.5 MHz | 14.6 dB/100m | 75.5 dB | 72.5 dB | 60.9 dB | 57.9 dB | 58.1 dB | 55.1 dB | 21.5 dB | 22 dB | |
100 MHz | 18.5 dB/100m | 72.4 dB | 69.4 dB | 53.9 dB | 50.9 dB | 54 dB | 51 dB | 20.1 dB | 20 dB | |
125 MHz | 20.8 dB/100m | 70.9 dB | 67.9 dB | 50.2 dB | 47.2 dB | 52.1 dB | 49.1 dB | 19.4 dB | 19 dB | |
200 MHz | 26.5 dB/100m | 67.9 dB | 64.9 dB | 41.4 dB | 38.4 dB | 48 dB | 45 dB | 18 dB | 17 dB | |
250 MHz | 29.7 dB/100m | 66.4 dB | 63.4 dB | 36.7 dB | 33.7 dB | 46 dB | 43 dB | 17.3 dB | 16 dB | |
300 MHz | 32.7 dB/100m | 65.2 dB | 62.2 dB | 32.6 dB | 29.6 dB | 44.5 dB | 41.5 dB | 17.3 dB | | |
500 MHz | 42.8 dB/100m | 61.9 dB | 58.9 dB | 19.2 dB | 16.2 dB | 40 dB | 37 dB | 17.3 dB | | |
600 MHz | 47.1 dB/100m | 60.7 dB | 57.7 dB | 13.6 dB | 10.6 dB | 38.4 dB | 35.4 dB | 17.3 dB | | |
Table Notes | Limits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009) |
---|
Coupling Attenuation Class | Type Ib |
---|
Transfer Impedance Class | Grade 2 |
---|
Voltage
Voltage Rating [V] |
---|
72 V DC |
Temperature Range
Installation Temperature Range | -5°C To +80°C |
---|
Operating Temperature Range | -40°C To +80°C |
---|
Mechanical Characteristics
Bending Test | Low temperature bending test -40 °C : No cracks |
---|
Pressure Test for Jacket | Test at high temperature IEC 60811-508 80±2 °C 4h : ≤ 50 % |
---|
Heat Stroke Test | Heat Shock test at (150±3°C ,1h) : No cracks |
---|
Bulk Cable Weight | 65.5 kg/km |
---|
Min. Bend Radius During Installation | 10*D |
---|
Standards
ISO/IEC Compliance | ISO/IEC 11801-2, IEC 60092-360 |
---|
CENELEC Compliance | EN 50173-1 |
---|
Data Category | Category 7 |
---|
ANSI Compliance | ANSI/TIA 568.2-D (2018) |
---|
IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
---|
Applicable Environmental and Other Programs
Environmental Space | Indoor |
---|
Suitability
Flammability, LS0H, Toxicity Testing
UL Flammability | UL1581 VW-1 |
---|
IEC Flammability | IEC 60332-1-2, IEC 60332-3-22 |
---|
Fluorine Content Test IEC60684-2 | HF ≤ 0.1% |
---|
IEC 60754-1 - Halogen Amount | HCL+HBr ≤ 0.5% |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 10 µS/mm |
---|
IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
---|
IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
---|
Product Notes
Footnote | *Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length. |
---|
Notes | LR (Lloyd’s Register) certification |
---|
History
Update and Revision | Revision Number: 0.50 Revision Date: 11-09-2022 |
---|
Documentation
Product Bulletins
Catalogs
Brochures
Guides
Videos
Training
Data Sheets