Marine Ethernet Cat 7, 4 Pr 23AWG Annealed Bare Copper, Foam Polyethylene Insulation, S/FTP, Low Smoke Zero Halogen (SHF1) Jacket, Indoor Shipboard, LR certified
Specifications
Specifications
Product Overview
| Suitable Applications | Shipbuilding, in-cabin passenger Wi-Fi, high-bandwidth IPTV, PoE lighting, device charging stations, onboard security cameras, etc. |
|---|
Physical Characteristics (Overall)
Conductor
| AWG | Stranding | Material | No. of Pairs |
|---|
| 23 | Solid | BC - Bare Copper | 4 |
| Conductor Count | 8 |
|---|
| Total Number of Pairs | 4 |
|---|
Insulation
| Material | Nominal Diameter |
|---|
| PO - Polyolefin (Foam) | 1.35 mm |
Color Chart
| Number | Color |
|---|
| Pair 1 | White & Blue |
| Pair 2 | White & Orange |
| Pair 3 | White & Green |
| Pair 4 | White & Brown |
Inner Shield
| Element | Type | Material | Coverage [%] |
|---|
| Individual Shielded Pair | Tape | Bi-Laminate (Alum+Poly) | 100% |
Outer Shield
| Type | Material | Coverage [%] | Drainwire Material | Drainwire AWG |
|---|
| Braid | Tinned Copper (TC) | 30% | Tinned Copper | 28 AWG |
Outer Jacket
| Material | Nominal Diameter | Diameter +/- Tolerance |
|---|
| LSZH - Low Smoke Zero Halogen (SHF1) | 7.8 mm | 0.3 mm |
Construction and Dimensions
| Min Elongation at Breakof Jacket | 125 % |
|---|
| Min Tensile Strength of Jacket | 9 MPa |
|---|
| Min Tensile Strength of Jacket Aged | 30 % |
|---|
| Min Elongation at Break of Jacket Aged | 30 % |
|---|
Electrical Characteristics
Conductor DCR
| Max. Conductor DCR | Max DCR Unbalanced Between Pairs [%] | Max. DCR Unbalanced Within Pair [%] |
|---|
| 95 Ohm/km | 4 % | 2 % |
Capacitance
| Max. Capacitance Unbalance | Max. Mutual Capacitance |
|---|
| 160 pF/100m | 56 pF/m |
| Insulation Resistance | 5000 MOhm.m |
|---|
Impedance
| Nominal Characteristic Impedance |
|---|
| 100 Ohm |
Delay
| Max. Delay Skew | Nominal Velocity of Propagation (VP) [%] |
|---|
| 25 ns/100m | 78% |
High Frequency
| Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. NEXT [dB] | Min. PSNEXT [dB] | Min. ACR [dB] | Min. PSACR [dB] | Min. ACRF (ELFEXT) [dB] | Min. PSACRF (PSELFEXT) [dB] | Min. RL (Return Loss) [dB] | Min. TCL [dB] | Min. ELTCTL [dB] |
|---|
| 1 MHz | 2.1 dB/100m | 78 dB | 75 dB | 75.9 dB | 72.9 dB | 78 dB | 75 dB | 20 dB | 40 dB | 35 dB |
| 4 MHz | 3.7 dB/100m | 78 dB | 75 dB | 74.3 dB | 71.3 dB | 78 dB | 75 dB | 23 dB | 34 dB | 23 dB |
| 10 MHz | 5.8 dB/100m | 78 dB | 75 dB | 72.2 dB | 69.2 dB | 74 dB | 71 dB | 25 dB | 30 dB | 15 dB |
| 16 MHz | 7.3 dB/100m | 78 dB | 75 dB | 70.7 dB | 67.7 dB | 69.9 dB | 66.9 dB | 25 dB | 28 dB | 10.9 dB |
| 31.3 MHz | 10.3 dB/100m | 78 dB | 75 dB | 67.7 dB | 64.7 dB | 64.1 dB | 61.1 dB | 23.6 dB | 25.1 dB | 5.1 dB |
| 62.5 MHz | 14.6 dB/100m | 75.5 dB | 72.5 dB | 60.9 dB | 57.9 dB | 58.1 dB | 55.1 dB | 21.5 dB | 22 dB | |
| 100 MHz | 18.5 dB/100m | 72.4 dB | 69.4 dB | 53.9 dB | 50.9 dB | 54 dB | 51 dB | 20.1 dB | 20 dB | |
| 125 MHz | 20.8 dB/100m | 70.9 dB | 67.9 dB | 50.2 dB | 47.2 dB | 52.1 dB | 49.1 dB | 19.4 dB | 19 dB | |
| 200 MHz | 26.5 dB/100m | 67.9 dB | 64.9 dB | 41.4 dB | 38.4 dB | 48 dB | 45 dB | 18 dB | 17 dB | |
| 250 MHz | 29.7 dB/100m | 66.4 dB | 63.4 dB | 36.7 dB | 33.7 dB | 46 dB | 43 dB | 17.3 dB | 16 dB | |
| 300 MHz | 32.7 dB/100m | 65.2 dB | 62.2 dB | 32.6 dB | 29.6 dB | 44.5 dB | 41.5 dB | 17.3 dB | | |
| 500 MHz | 42.8 dB/100m | 61.9 dB | 58.9 dB | 19.2 dB | 16.2 dB | 40 dB | 37 dB | 17.3 dB | | |
| 600 MHz | 47.1 dB/100m | 60.7 dB | 57.7 dB | 13.6 dB | 10.6 dB | 38.4 dB | 35.4 dB | 17.3 dB | | |
| Table Notes | Limits below 4 MHz are for information only. Reference standard: ISO/IEC 61156-5 ed. 2.0 (2009) |
|---|
| Coupling Attenuation Class | Type Ib |
|---|
| Transfer Impedance Class | Grade 2 |
|---|
Voltage
| Voltage Rating [V] |
|---|
| 72 V DC |
Temperature Range
| Installation Temperature Range | -5°C To +80°C |
|---|
| Operating Temperature Range | -40°C To +80°C |
|---|
Mechanical Characteristics
| Bending Test | Low temperature bending test -40 °C : No cracks |
|---|
| Pressure Test for Jacket | Test at high temperature IEC 60811-508 80±2 °C 4h : ≤ 50 % |
|---|
| Heat Stroke Test | Heat Shock test at (150±3°C ,1h) : No cracks |
|---|
| Bulk Cable Weight | 65.5 kg/km |
|---|
| Min. Bend Radius During Installation | 10*D |
|---|
Standards
| ISO/IEC Compliance | ISO/IEC 11801-2, IEC 60092-360 |
|---|
| CENELEC Compliance | EN 50173-1 |
|---|
| Data Category | Category 7 |
|---|
| ANSI Compliance | ANSI/TIA 568.2-D (2018) |
|---|
| IEEE Compliance | IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 |
|---|
Applicable Environmental and Other Programs
| Environmental Space | Indoor |
|---|
Suitability
Flammability, LS0H, Toxicity Testing
| UL Flammability | UL1581 VW-1 |
|---|
| IEC Flammability | IEC 60332-1-2, IEC 60332-3-22 |
|---|
| Fluorine Content Test IEC60684-2 | HF ≤ 0.1% |
|---|
| IEC 60754-1 - Halogen Amount | HCL+HBr ≤ 0.5% |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity | 10 µS/mm |
|---|
| IEC 60754-2 - Halogen Acid Gas Amount - Min. pH | 4.3 |
|---|
| IEC 61034-2 - Smoke Density Min. Transmittance | 60% |
|---|
Product Notes
| Footnote | *Ordering stock code will be created at the time of placing the order and the stock code will include cable part code, outer jacket color & putup length. |
|---|
| Notes | LR (Lloyd’s Register) certification |
|---|
History
| Update and Revision | Revision Number: 0.50 Revision Date: 11-09-2022 |
|---|