Belden

29016 - ACIC 600V, 50+G C #16 Str BC, XLPE Ins, PVC Jkt, AIA Armor, Blu PVC Jkt, 90C Dry/Wet SUN RES -40C

(No reviews yet) Write a Review
SKU:
29016
Shipping:
Calculated at Checkout
$0.00

Description

Canadian Instrumentation Cable TC-ACIC 600V, 50+G Conductor 16AWG (7x24) Bare Copper, XLPE Insulation, PVC Inner Jacket, Aluminum Interlock Armor, Blue PVC Outer Jacket, 90C Dry/Wet SUN RES -40C

Specifications

Specifications

Put-Up TypeReel

Physical Characteristics (Overall)

Conductor

ElementAWGStrandingMaterialNo. of Conductors
Conductor(s)167x24BC - Bare Copper50
Ground167x24BC - Bare Copper1
Conductor Count50

Insulation

Material
XLP, XLPO, XLPE (Thermoset)
XLP, XLPO, XLPE (Thermoset)

Color Chart

NumberColor
1White and Numbered 1
2Black and Numbered 2
3Black and Numbered 3
4Black and Numbered 4
5Black and Numbered 5
6Black and Numbered 6
7Black and Numbered 7
8Black and Numbered 8
9Black and Numbered 9
10Black and Numbered 10
11Black and Numbered 11
12Black and Numbered 12
13Black and Numbered 13
14Black and Numbered 14
15Black and Numbered 15
16Black and Numbered 16
17Black and Numbered 17
18Black and Numbered 18
19Black and Numbered 19
20Black and Numbered 20
21Black and Numbered 21
22Black and Numbered 22
23Black and Numbered 23
24Black and Numbered 24
25Black and Numbered 25
26Black and Numbered 26
27Black and Numbered 27
28Black and Numbered 28
29Black and Numbered 29
30Black and Numbered 30
31Black and Numbered 31
32Black and Numbered 32
33Black and Numbered 33
34Black and Numbered 34
35Black and Numbered 35
36Black and Numbered 36
37Black and Numbered 37
38Black and Numbered 38
39Black and Numbered 39
40Black and Numbered 40
41Black and Numbered 41
42Black and Numbered 42
43Black and Numbered 43
44Black and Numbered 44
45Black and Numbered 45
46Black and Numbered 46
47Black and Numbered 47
48Black and Numbered 48
49Black and Numbered 49
50Black and Numbered 50

Inner Jacket

MaterialNominal Diameter
PVC - Polyvinyl Chloride1.19 in

Outer Jacket

MaterialNominal Diameter
PVC - Polyvinyl Chloride1.540 in
1.54 in

Construction and Dimensions

Armor

Type of ArmorMaterialDiameter over Armoring
InterlockedAluminum1.45 in

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR
4.2 Ohm/1000ft

Current

Max. Recommended Current [A]
5 Amps per Conductor at 25ºC

Voltage

Non-UL Voltage Rating
600 V RMS

Temperature Range

Non-UL Temp Rating90°C
UL Temp RatingN/A
Operating Temperature Range-40°C To +90°C
Wet Temp Range-40°C To +90 °C
Dry Temp Range-40°C To +90 °C

Mechanical Characteristics

UV ResistanceYes
Bulk Cable Weight1306 lbs/1000ft
Max. Pull Tension843 lbs
Min. Bend Radius/Minor Axis18.8 in

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV)Yes
EU Directive 2003/96/EC (BFR)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU Directive ComplianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHS)Yes

Suitability

Suitability - BurialYes
Suitability - Hazardous LocationsYes
Suitability - IndoorYes
Suitability - OutdoorYes
Suitability - Sunlight ResistanceYes

Flammability, LS0H, Toxicity Testing

UL voltage ratingN/A

Plenum/Non-Plenum

Plenum (Y/N)No

History

Update and RevisionRevision Number: 0.196 Revision Date: 04-08-2022
View AllClose